THERMOTRON FM-16-CHM-5-5
    说明
    Refrigeration hours 99,000+ Refrigerant: R23/R404A Power requirement: 480V/24A three phase Other facilities requirements: water for humidity system. Drain. There's no air purge on this chamber. Cooling: Water cooled; 1" NPT connections are provided. This chamber requires a fair amount of water at room temp in order to run at full capacity. Interior dimensions: 23.5" wide, 36.5" deep, 32" high Compressors: Two Copeland 5hp, bolted construction. Chamber heat: 4.5kW Steam generator: 4.5kW Humidity sensor: wet wick Controller: Thermotron 4800 it achieved -25C from 20C in five minutes; a further seven minutes resulted in -50C. Nine minutes were required to reach -60C from -50C. The heater works; it draws 6A at 480V three-phase. The steam generator shows good continuity. The humidity sensor does not work and the humidity coil did not energize when we enabled humidity in the control. The humidity water fill does work. A tag by the data plate states a refrigerant conversion was performed in 1995 from R13/R502 to R23/R404A. At this time a refrigerant expansion tank was added at the top of the chamber. Apparently, the 4800 control is original to this unit; it has several option cards including GPIB. The chart recorder is a Truline by Honeywell; it seems to work but we did not have a paper to test it with. A Destaco latch was installed to remedy a door leak. No manual or shelves are included.
    配置
    无配置
    OEM 型号描述
    未提供
    文件

    无文件

    THERMOTRON

    FM-16-CHM-5-5

    verified-listing-icon

    已验证

    类别
    Environmental Chambers

    上次验证: 60 多天前

    物品主要详细信息

    状况:

    Used


    运行状况:

    未知


    产品编号:

    52017


    晶圆尺寸:

    未知


    年份:

    1981


    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    类似上架物品
    查看全部
    THERMOTRON FM-16-CHM-5-5

    THERMOTRON

    FM-16-CHM-5-5

    Environmental Chambers
    年份: 1981状况: 二手
    上次验证60 多天前

    THERMOTRON

    FM-16-CHM-5-5

    verified-listing-icon
    已验证
    类别
    Environmental Chambers
    上次验证: 60 多天前
    listing-photo-5ae5c270363e4d9c8a9220cf50dd1a9c-https://d2pkkbyngq3xpw.cloudfront.net/moov_media/3.0-assets/photo-coming-soon-small.png
    物品主要详细信息

    状况:

    Used


    运行状况:

    未知


    产品编号:

    52017


    晶圆尺寸:

    未知


    年份:

    1981


    Have Additional Questions?
    Logistics Support
    Available
    Money Back Guarantee
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    说明
    Refrigeration hours 99,000+ Refrigerant: R23/R404A Power requirement: 480V/24A three phase Other facilities requirements: water for humidity system. Drain. There's no air purge on this chamber. Cooling: Water cooled; 1" NPT connections are provided. This chamber requires a fair amount of water at room temp in order to run at full capacity. Interior dimensions: 23.5" wide, 36.5" deep, 32" high Compressors: Two Copeland 5hp, bolted construction. Chamber heat: 4.5kW Steam generator: 4.5kW Humidity sensor: wet wick Controller: Thermotron 4800 it achieved -25C from 20C in five minutes; a further seven minutes resulted in -50C. Nine minutes were required to reach -60C from -50C. The heater works; it draws 6A at 480V three-phase. The steam generator shows good continuity. The humidity sensor does not work and the humidity coil did not energize when we enabled humidity in the control. The humidity water fill does work. A tag by the data plate states a refrigerant conversion was performed in 1995 from R13/R502 to R23/R404A. At this time a refrigerant expansion tank was added at the top of the chamber. Apparently, the 4800 control is original to this unit; it has several option cards including GPIB. The chart recorder is a Truline by Honeywell; it seems to work but we did not have a paper to test it with. A Destaco latch was installed to remedy a door leak. No manual or shelves are included.
    配置
    无配置
    OEM 型号描述
    未提供
    文件

    无文件

    类似上架物品
    查看全部
    THERMOTRON FM-16-CHM-5-5

    THERMOTRON

    FM-16-CHM-5-5

    Environmental Chambers年份: 1981状况: 二手上次验证:60 多天前