
说明
无说明配置
CAS 140D Array Spectrometer Model VIS (CAS140D151U1A) • 1024 x 128 pixel (binning mode) back- illuminated CCD detector • Shortest integration time approx. 4 ms • Built-in shutter and order sorting filter • AD-converter with 24 Bit resolution (chip 16 Bit) • Detector cooling to -10°C • Modell VIS • Wavelength range 360 – 830 nm • Spectral resolution 2.2 nm (100 μm slit) • 0.5 nm/pixel data-point interval • PC-interface: USB 2.0 • 100 μm entrance slit • Filter wheel with density filters OD1, OD2, OD3, OD4 SpecWin Light spectral software - SW-120 DLL Driver Program - SW-231 Integrating sphere with 100 mm internal diameter, measurement port 33 mm diam., connector for fiber bundle; BaSO4 coating, spectral range 240 to 2600 nm; version for mounting on a mechanical sorter or prober (ISP100-130) Fiber bundle, 1.5 mm diam., 3 m long; quartz, spectral range 190 to 1350 nm (OFG-424-3) Fiber-bundle adaptor optimized for UV; spectral range 190 to 3200 nm, supports accessory recognition with CAS 140D (PLG-421) Calibration of the input port of integrating spheres in illuminance; calibration certificate for irradiance; calibration file converted to luminous flux; wavelength range VIS/NIR (CAL-144) Integrating sphere with 500 mm diameter; (ISP500-100) for measuring luminous and radiant flux of lamps, LEDs and LED clusters · hinges for easy opening and closing of the sphere · barium sulphate coating · teflon lamp post with banana socket for mounting the sample adapter in the center of the sphere · entrance port with 150 mm diameter, for mounting the sample from outside of the sphere; the entrance port can be closed · halogen auxiliary lamp with socket · adapter for fiber bundle (without fiber bundle) Fiber bundle, 1.5 mm diam., 3 m long; quartz, spectral range 190 to 1350 nm (OFG-424-3) Fiber-bundle adaptor optimized for UV; spectral range 190 to 3200 nm, supports accessory recognition with CAS 140D (PLG-421) Sample stage (100 mm x 100 mm) for mounting larger samples inside the sphere; including 4 pole strip terminal for electrical connection; to be mounted on the internal lamp post (ISP500-400) Options: Adapter flange for the 150 mm measurement port; includes adapter for the LED-870 TEC mount for small LED modules (ISP500-225) Laboratory power supply for auxiliary lamps in integrating spheres and for tungsten halogen lamps in RMH, TRA and ISP150; 0-42 V / 0-6 A / 100 W; 100- 240 V mains supply (PS-102)OEM 型号描述
未提供文件
无文件
VEECO
SPHERE
类别
Spectrometer / SIMS
上次验证: 3 天前
物品主要详细信息
状况:
Used
运行状况:
未知
产品编号:
133619
晶圆尺寸:
未知
年份:
未知
Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
说明
无说明配置
CAS 140D Array Spectrometer Model VIS (CAS140D151U1A) • 1024 x 128 pixel (binning mode) back- illuminated CCD detector • Shortest integration time approx. 4 ms • Built-in shutter and order sorting filter • AD-converter with 24 Bit resolution (chip 16 Bit) • Detector cooling to -10°C • Modell VIS • Wavelength range 360 – 830 nm • Spectral resolution 2.2 nm (100 μm slit) • 0.5 nm/pixel data-point interval • PC-interface: USB 2.0 • 100 μm entrance slit • Filter wheel with density filters OD1, OD2, OD3, OD4 SpecWin Light spectral software - SW-120 DLL Driver Program - SW-231 Integrating sphere with 100 mm internal diameter, measurement port 33 mm diam., connector for fiber bundle; BaSO4 coating, spectral range 240 to 2600 nm; version for mounting on a mechanical sorter or prober (ISP100-130) Fiber bundle, 1.5 mm diam., 3 m long; quartz, spectral range 190 to 1350 nm (OFG-424-3) Fiber-bundle adaptor optimized for UV; spectral range 190 to 3200 nm, supports accessory recognition with CAS 140D (PLG-421) Calibration of the input port of integrating spheres in illuminance; calibration certificate for irradiance; calibration file converted to luminous flux; wavelength range VIS/NIR (CAL-144) Integrating sphere with 500 mm diameter; (ISP500-100) for measuring luminous and radiant flux of lamps, LEDs and LED clusters · hinges for easy opening and closing of the sphere · barium sulphate coating · teflon lamp post with banana socket for mounting the sample adapter in the center of the sphere · entrance port with 150 mm diameter, for mounting the sample from outside of the sphere; the entrance port can be closed · halogen auxiliary lamp with socket · adapter for fiber bundle (without fiber bundle) Fiber bundle, 1.5 mm diam., 3 m long; quartz, spectral range 190 to 1350 nm (OFG-424-3) Fiber-bundle adaptor optimized for UV; spectral range 190 to 3200 nm, supports accessory recognition with CAS 140D (PLG-421) Sample stage (100 mm x 100 mm) for mounting larger samples inside the sphere; including 4 pole strip terminal for electrical connection; to be mounted on the internal lamp post (ISP500-400) Options: Adapter flange for the 150 mm measurement port; includes adapter for the LED-870 TEC mount for small LED modules (ISP500-225) Laboratory power supply for auxiliary lamps in integrating spheres and for tungsten halogen lamps in RMH, TRA and ISP150; 0-42 V / 0-6 A / 100 W; 100- 240 V mains supply (PS-102)OEM 型号描述
未提供文件
无文件