    Known issues: LLTC circulation pump has failed LC power supply unit STAKPAK2 IST4-1404-W01 (600 W) has failed System: VAX 4000/96 Wafer stage: 6” chuck Reticle alignment: ISS / SRA / VRA Wafer alignment: LSA / FIA Cassettes: Left / right / extra Control rack position: Right Reticle loader: 5” reticle size; option library; 24 slots Auto focus: Multi Wafer loader: Type 2 A3 OF type: Flat Flatzone direction: 6 o’clock In-line: No PPD: Installed Barcode system: Installed Environment chamber: Asahi N2A-D Illumination: SLOT1, CONV ID; L-NA 0.57; I-NA 0.34 Hg lamp illumination: 632.847 mW/cm² average; 1.150% uniformity Wafer local flatness: 0.690 µm Lens distortion: X maximum 0.019 µm; X minimum -0.020 µm; Y maximum 0.013 µm; Y minimum -0.047 µm Stepping: X 3σ 0.020 µm; Y 3σ 0.023 µm; X backlash 3σ 0.027 µm; Y backlash 3σ 0.023 µm Software: MCSV Ver.231D; OCSV Ver.231A; TOOL Ver.243B Base kit: BASE7_101-0306A Reticle barcode reader: Nikon Code Alignment sensors: LSA / FIA, 15/20 mm field Workstation: VAX Station 4000.96 (VS49K-AC) Environment chamber: N2A-D; dated 2/1996
    OEM 型号描述
    The NSR-2205i11C is equipped with a resolution of 450nm or better and features a numerical aperture (NA) of 0.57. It utilizes an i-line (365nm) exposure light source and has a reduction ratio of 1:5. The exposure field ranges from a 22mm square to 17.9(H) x 25.2(V)mm. The alignment accuracy, using the EGA method, is 70nm or better. The system comes with the LSA alignment system as standard and offers the optional FIA and LIA alignment systems.
    文件

    无文件

    verified-listing-icon

    已验证

    类别
    Steppers & Scanners

    上次验证: 25 天前

    物品主要详细信息

    状况:

    Used


    运行状况:

    未知


    产品编号:

    153211


    晶圆尺寸:

    6"/150mm


    年份:

    1997


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    类似上架物品
    查看全部
    NIKON NSR-2205i11C

    NIKON

    NSR-2205i11C

    Steppers & Scanners
    年份: 1997状况: 二手
    上次验证25 天前

    NIKON

    NSR-2205i11C

    verified-listing-icon
    已验证
    类别
    Steppers & Scanners
    上次验证: 25 天前
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392137/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392133/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392141/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392135/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392150/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392140/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392136/image/md.jpg
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392146/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392142/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392139/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392143/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392144/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392131/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392147/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392148/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392149/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392132/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392134/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392145/image/md.png
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392138/image/md.jpg
    listing-photo-7714281344854e7ba5fd8a0d120f7a79-https://api-v2.moov.co/listingPhotos/392130/image/md.jpg
    物品主要详细信息

    状况:

    Used


    运行状况:

    未知


    产品编号:

    153211


    晶圆尺寸:

    6"/150mm


    年份:

    1997


    Logistics Support
    Available
    Transaction Insured by Moov
    Available
    Refurbishment Services
    Available
    说明
    i-line stepper
    配置
    Known issues: LLTC circulation pump has failed LC power supply unit STAKPAK2 IST4-1404-W01 (600 W) has failed System: VAX 4000/96 Wafer stage: 6” chuck Reticle alignment: ISS / SRA / VRA Wafer alignment: LSA / FIA Cassettes: Left / right / extra Control rack position: Right Reticle loader: 5” reticle size; option library; 24 slots Auto focus: Multi Wafer loader: Type 2 A3 OF type: Flat Flatzone direction: 6 o’clock In-line: No PPD: Installed Barcode system: Installed Environment chamber: Asahi N2A-D Illumination: SLOT1, CONV ID; L-NA 0.57; I-NA 0.34 Hg lamp illumination: 632.847 mW/cm² average; 1.150% uniformity Wafer local flatness: 0.690 µm Lens distortion: X maximum 0.019 µm; X minimum -0.020 µm; Y maximum 0.013 µm; Y minimum -0.047 µm Stepping: X 3σ 0.020 µm; Y 3σ 0.023 µm; X backlash 3σ 0.027 µm; Y backlash 3σ 0.023 µm Software: MCSV Ver.231D; OCSV Ver.231A; TOOL Ver.243B Base kit: BASE7_101-0306A Reticle barcode reader: Nikon Code Alignment sensors: LSA / FIA, 15/20 mm field Workstation: VAX Station 4000.96 (VS49K-AC) Environment chamber: N2A-D; dated 2/1996
    OEM 型号描述
    The NSR-2205i11C is equipped with a resolution of 450nm or better and features a numerical aperture (NA) of 0.57. It utilizes an i-line (365nm) exposure light source and has a reduction ratio of 1:5. The exposure field ranges from a 22mm square to 17.9(H) x 25.2(V)mm. The alignment accuracy, using the EGA method, is 70nm or better. The system comes with the LSA alignment system as standard and offers the optional FIA and LIA alignment systems.
    文件

    无文件

    类似上架物品
    查看全部
    NIKON NSR-2205i11C

    NIKON

    NSR-2205i11C

    Steppers & Scanners年份: 1997状况: 二手上次验证:25 天前
    NIKON NSR-2205i11C

    NIKON

    NSR-2205i11C

    Steppers & Scanners年份: 0状况: 翻新上次验证:60 多天前
    NIKON NSR-2205i11C

    NIKON

    NSR-2205i11C

    Steppers & Scanners年份: 0状况: 二手上次验证:60 多天前