ONTO / NANOMETRICS / ACCENT / BIO-RAD NANOSPEC 6100
  • ONTO / NANOMETRICS / ACCENT / BIO-RAD NANOSPEC 6100
说明
无说明
配置
无配置
OEM 型号描述
The NanoSpec 6100 is a tabletop film analysis system that provides fast and low-cost measurement capabilities for thin film metrology. It uses non-contact spectroscopic reflectometry to measure sites as small as 10µm in diameter on production wafers and can measure wafer substrates in the size range of 75 to 200mm and photomasks from 5 to 9 inches square. The system can measure film thickness in the range of 200Å - 20µm with the visible light source and 25Å - 20µm with an optional UV light source. The upper thickness range can be extended to 70µm with the thick film option. The system also has a motorized, precision x-y sample stage with a resolution of better than 1µm and a high-resolution color graphics display that provides contour and 3D film thickness mapping.
文件

无文件

类别
Thin Film / Film Thickness

上次验证: 60 多天前

物品主要详细信息

状况:

Used


运行状况:

未知


产品编号:

115126


晶圆尺寸:

8"/200mm


年份:

未知


Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available

ONTO / NANOMETRICS / ACCENT / BIO-RAD

NANOSPEC 6100

verified-listing-icon
已验证
类别
Thin Film / Film Thickness
上次验证: 60 多天前
listing-photo-0061da4d60054fec97f7920817e94d75-https://media-moov-co.s3.us-west-1.amazonaws.com/user_media/listingPhoto/1987/0061da4d60054fec97f7920817e94d75/c1bbf1298b8a44dcb30641e0163f9183_spk39100_mw.png
物品主要详细信息

状况:

Used


运行状况:

未知


产品编号:

115126


晶圆尺寸:

8"/200mm


年份:

未知


Logistics Support
Available
Transaction Insured by Moov
Available
Refurbishment Services
Available
说明
无说明
配置
无配置
OEM 型号描述
The NanoSpec 6100 is a tabletop film analysis system that provides fast and low-cost measurement capabilities for thin film metrology. It uses non-contact spectroscopic reflectometry to measure sites as small as 10µm in diameter on production wafers and can measure wafer substrates in the size range of 75 to 200mm and photomasks from 5 to 9 inches square. The system can measure film thickness in the range of 200Å - 20µm with the visible light source and 25Å - 20µm with an optional UV light source. The upper thickness range can be extended to 70µm with the thick film option. The system also has a motorized, precision x-y sample stage with a resolution of better than 1µm and a high-resolution color graphics display that provides contour and 3D film thickness mapping.
文件

无文件